Z8018x
Family MPU User Manual
278
UM005003-0703
TST g**
MC1 T1T2T3 1st Op Code
Address
1st Op
Code
010 1 01 0
MC2 T1T2T3 2nd Op Code
Address
2nd Op
Code
010 1 01 1
MC3 Ti * Z 111 1 11 1
TST m**
MC1 T1T2T3 1st Op Code
Address
1st Op
Code
010 1 01 0
MC2 T1T2T3 2nd Op Code
Address
2nd Op
Code
010 1 01 1
MC3 T1T2T3 1st operand
Address
m 010 1 11 1
TST (HL)** MC1 T1T2T3 1st Op Code
Address
1st Op
Code
020 2 02 0
MC2 T1T2T3 2nd Op Code
Address
2nd Op
Code
010 1 01 1
MC3 Ti * Z 111 1 11 1
MC4 T1T23HL Data 010 1 11 1
Table 51. Bus and Control Signal Condition in Each Machine Cycle (Continued)
Instruction
Machine
Cycle States Address Data RD WR MREQ IORQ M1 HALT ST
Kommentare zu diesen Handbüchern