Z80 Instruction Set UM008007-0715
188
Z80 CPU
User Manual
ADC HL, ss
Operation
HL HL + ss + CY
Op Code
ADC
Operands
HL, ss
Description
The contents of register pair ss (any of register pairs BC, DE, HL, or SP) are added with
the Carry flag (C flag in the F Register) to the contents of register pair HL, and the result is
stored in HL. In the assembled object code, operand ss is specified as follows:
Condition Bits Affected
S is set if result is negative; otherwise, it is reset.
Z is set if result is 0; otherwise, it is reset.
H is set if carry from bit 11; otherwise, it is reset.
P/V is set if overflow; otherwise, it is reset.
Register
Pair ss
BC
00
DE
01
HL
10
SP
11
M Cycles T States 4 MHz E.T.
4 15 (4, 4, 4, 3) 3.75
11 0 01111
ED
01 s 100s1
Seitenansicht 199