Z80 Instruction Set UM008007-0715
158
Z80 CPU
User Manual
r identifies registers B, C–, D, E, H, L, or A specified in the assembled object code field,
as follows:
Description
A logical OR operation is performed between the byte specified by the s operand and the
byte contained in the Accumulator; the result is stored in the Accumulator.
Condition Bits Affected
S is set if result is negative; otherwise, it is reset.
Z is set if result is 0; otherwise, it is reset.
H is reset.
P/V is set if overflow; otherwise, it is reset.
N is reset.
C is reset.
Example
If the H Register contains 48h (0100 0100), and the Accumulator contains 12h (0001
0010), then upon the execution of an OR H instruction, the Accumulator contains 5Ah
(
0101 1010).
Register r
B 000
C 001
D 010
E 011
H 100
L 101
A 111
Instruction M Cycles T States 4 MHz E.T.
OR r 1 4 1.00
OR n 2 7 (4, 3) 1.75
OR (HL) 2 7 (4, 3) 1.75
OR (IX+d) 5 19 (4, 4, 3, 5, 3) 4.75
OR (lY+d) 5 19 (4, 4, 3, 5, 3) 4.75