UM001604-0108 External Interface
137
Extended Bus Timing
Some products can accommodate slow memory access time by automatically inserting an
additional software controlled state time (Tx). This stretches the DS
timing by two clock
periods. Figure 128 and Figure 129 on page 138 display extended external memory Read
and Write cycles.
Figure 128. Extended External Instruction Fetch or Memory Read Cycle
Machine Cycle
T2*
TX
T3
Clock
A15-A8
AD7–AD0
AS
DS
R/W
DM
Read Cycle
A15-A8
A7–A0
D7–D0 IN
T1
*
Port inputs are strobed during T2, which is two internal system clocks
before the execution of the current instruction.