Using the ZGATE Web Interface UM024502-1012
42
ZGATE Embedded Security Development Kit
User Manual
If the root folder of the file system does not contain a file named zg_rules.usr, then
during system startup, ZGATE will search for a file named
zg_rules.def in the root
folder of the file system. If that file is not found, or if ZFS support is not included in the
ZTP application, ZGATE will read its initial configuration settings from the
ZGATE_Conf.c file that was linked to the ZTP application.
ZGATE Logging Page
The ZGATE Logging Configuration page is used to turn on/off logging to the ZTP console
and/or to the Zilog File System (ZFS).
An example of the ZGATE Threshold filtering page is shown in Figure 12.
To enable (or disable) console logging, click the
Enable (or Disable) radio button to the
right of the Console Logging information, then click the
Update button. To enable (or dis-
Figure 12. The ZGATE Logging Configuration Page